Kaiser announces the RamanRxn2 „·1000 Analyzer
ANN ARBOR, MI (May 27, 2010) - Kaiser is pleased to announce the release of the
RamanRxn2„·1000 Raman analyzer.
The RamanRxn2„· 1000 analyzer provides the fluorescence rejection of a FT-Raman
spectrometer but with the ease of fiber-optic interfacing of a dispersive Raman analyzer. Using 1000 nm excitation is a compromise between fluorescence rejection and detection sensitivity. For non-Raman spectroscopists the observation of any level of fluorescence background can lead to a desire to move to a different excitation wavelength. However it is often possible to remove the background during a data analysis step leaving a residual spectrum of high enough signal-to-noise
ratio to allow quantitative analysis.
While 785-nm excitation remains the most universal wavelength for petrochemical and pharmaceutical Raman applications, some applications for example early stage ˇ§dirtyˇ¨ crystallization, biofuels, polyurethanes, heavy hydrocarbons, and some colorants / pigments exhibit fluorescence too intense to allow the application to be addressed with 785-nm excitation. For these applications the RamanRxn2„· 1000 analyzer provides an effective route for in situ monitoring.
In order to optimize performance in this wavelength range and bring this analyzer to market it was necessary to incorporate developments in
a. Diode lasers
b. InGaAs array detectors
c. Refractive axial transmissive spectrographs
d. Reaction analysis software
in order to obtain maximize detected Raman signals.
ˇ§The RamanRxn2„· 1000 Raman analyzer fills a niche for Raman analyzers for application
where fluorescence cannot be overcome using 785-nm excitation. In certain cases a Raman
method had to be employed off-line because the only available instrumentation capable of
overcoming sample fluorescence was an FT-Raman spectrometer.
With the introduction of the RamanRxn2„· 1000 Raman analyzer these Raman measurements can be made on-line
allowing users the potential to develop process control methodologies rather than end-product testing,ˇ¨ says Ian Lewis, Marketing Manager at Kaiser.
This analyzer is offered with either iC RamanTM 4.1 for reaction development and understanding, or synTQ-Lite for process monitoring and control where compliance to 21 CFR Part 11 and interface to data historians are required.
About Kaiser Optical Systems
Kaiser Optical Systems, Inc., a wholly owned subsidiary of Rockwell Collins (NYSE:
COL), is a leader in the design and production of holographic optical elements, Raman
analyzers and components for spectroscopy. The company was formed in 1979 and has
over 18 years of experience in Raman spectroscopy with customers located around the world.
Additional company and product information is available at www.kosi.com.
Rockwell Collins (NYSE: COL) is a pioneer in the development and deployment of
innovative communication and aviation electronic solutions for both commercial and
government applications. Our expertise in flight deck avionics, cabin electronics, mission
communications, information management, and simulation and training is delivered by
20,000 employees, and a global service and support network that crosses 27 countries. To
find out more, please visit
www.rockwellcollins.com.
For Kaiser
Contact Ian R. Lewis
Kaiser Optical Systems, Inc.
Address 371 Parkland Plaza
Ann Arbor, MI 48103 USA
Tel + 1 734 665 8083
Fax + 1 734 665 8199
Email marketing@kosi.com
Internet www.kosi.com
|